   VacuClear 
  Now with INVIZO-GUARD

The hands off tablet, eliminating end of the day chemical rinsing for GOOD! 
Our State of the Art Patent , as well Patent Pending
Simple Detailed Step by Step Directions -Takes Only 10 MINUTES PER WEEK!

Non -Toxic -Non-Corrosive-Non-Foaming-Eliminates Odors

1. Twice per week, turn off the main va

2. In each treatment-room remove all solids-collector lids, found near or by chair-side. Rinse or replace collector screens.

3. Drop one VacuClear™ tablet on each collector screen, close all collector lids.

4. Turn on main vacuum pump, tablets will self-activate each and every time the high or low speed lines are used.  

  Messy or Bloody procedures 

  In-Between Rinse​

  Ask about our latest product! VacuClear Liquid™  
  ​
​ High, and Low speed lines are protected by our Scientifically proven theory. 
 INVIZO-GUARD! Patent Pending  
  Yet if the need to rinse 
, ​
1. Insert the H or L speed line, submerging in solution only 3 to 4 seconds. Remember VacuClear's inner quads have a base formula used in Hospital's around the world for its potent kill claims of germs, such as HIV -HEP-C-B and many other germs.Eliminates in seconds 

VacuClear™ Also eliminate odors not by covering them with fragrances ! 
Drop one tablet in cuspidors, and be amazed how not only it will remove those odors it will also aid in dual collector cuspidor lines. Keeping your complete system fresh clean, and free flowing!
VacuShock With INVIZO-GUARD Instructions

1. Turn Off Main Vacuum Pump. 

2. While main pump is off prepare all treatment rooms for the VacuShock treatment.

3. Remove solids-collector lids in each treatment room, found near or by chair-side. Rinse or replace collector screens.

4. Place one VacuShock tablet in each solids collector, close lids.

5. Starting with the closest treatment room to the main pump! Fill a one-gallon container with warm to hot water if available. Drop one VacuShock tablet in gallon container, allow only 3 minutes dissolving time only. remainder of tablet reuse.

6. Using the H-Vac line, submerge in gallon solution for approx. 8 to 10 seconds, allowing air to enter line. Re-submerge until entire gallon has been consumed. NOTE: It is very common for suction to stop completely. 
If suction stops simply,
turn off main vacuum pump and empty pump’s collector trap. When this happens you will see all of the contaminated debris that has been harboring in your system.
(note) Non-conventional, simple wait a few minutes as your holding tank automatically drains.

8. Continue this process till suction is at peak level. Continue to next operatory, only adding a VacuShock tablet in container if tablet is completely gone

9. Repeat steps in each treatment room until system runs clear.  